Products Description
The working principle of the two-chamber impact test chamber is based on the principle of temperature change and heat transfer in thermodynamics. In the test process, the test sample is first placed in a box (usually a high temperature box or a low temperature box), so that it reaches the set initial temperature and is held for a period of time. Then, through an automated control system, the sample is quickly transferred to another box (low temperature box or high temperature box), thus achieving a rapid shock of temperature. This rapid temperature change simulates the extreme temperature environments that the product may encounter in actual use, such as a sudden transition from a hot outdoor environment to a cold indoor environment, or vice versa. By repeating this temperature shock cycle many times, it is possible to detect changes in the physical properties, electrical properties and structural integrity of the product under different temperature conditions.

Performance characteristics
Wide temperature range: The Two Box Impact Test Chamber can achieve a wide temperature range, usually covering a temperature range from -70 ° C to +180 ° C or wider, to meet the temperature impact test needs of various products in different industries. Whether it is in the extremely cold low temperature environment or in the harsh conditions of high temperature, it can accurately simulate the actual application scenario.
Fast temperature conversion: One of its core advantages is the ability to achieve extremely fast temperature conversion rates. In general, devices can make the transition from high to low temperature or from low to high temperature in seconds to minutes, which is critical for accurately assessing a product's ability to respond to temperature shocks. The rapid temperature conversion can more truly reproduce the sudden temperature changes that the product may encounter in actual use, so as to more effectively detect the potential quality problems and reliability defects of the product.
High precision temperature control: Equipped with advanced temperature control system, using high precision temperature sensor and intelligent control algorithm, can accurately control the temperature in the box. In the whole temperature shock test process, the temperature fluctuation can be controlled within a very small range, usually up to ±1℃ or even higher accuracy, to ensure the accuracy and reliability of the test results.
Good stability and repeatability: the carefully designed and optimized mechanical structure and stable control system make the equipment have excellent stability during long-term operation. When the same temperature shock test is repeated many times, the highly consistent test results can be obtained, which is of great significance for the evaluation and comparison of product quality. Whether it is the performance test of new products in the research and development stage, or the quality inspection of products in the production process, it can provide reliable data support.
User-friendly operation interface: In order to facilitate user operation and monitoring of the test process, the equipment is usually equipped with intuitive and easy-to-understand user-friendly operation interface. By touching the display screen or computer control system, the user can easily set the test parameters, such as temperature range, the number of impact cycles, residence time, etc., and real-time monitoring of temperature changes in the box, test time and other important information. At the same time, the equipment also has the fault diagnosis and alarm function, once the abnormal situation, can remind the user in time and take appropriate protective measures to ensure the safety of the test.
Application field
Electronics industry: In the development and production process of electronic products, Two Box Impact Chamber is widely used to test the reliability of integrated circuits, circuit boards, electronic components and other products. Temperature shock test can detect the electrical performance of electronic equipment under different temperature conditions, welding reliability and the adaptability of packaging materials, helping enterprises to improve product quality and reduce the failure rate of products during use.
Automotive industry: Automotive parts will face a variety of complex environmental conditions in actual use, and temperature shock is one of them. The two-box impact test chamber can be used to test the durability and reliability of automotive engine, transmission, sensor, instrument panel and other components. By simulating the temperature changes that the car may encounter when driving in different climate regions, the performance of the parts in extreme temperature environments is evaluated, and the safety and reliability of the car are guaranteed.
Aerospace: Aerospace equipment requires extremely high reliability and safety, and any minor failure can lead to serious consequences. The Two Box Impact Chamber is mainly used in the aerospace field to test the performance of aircraft parts, spacecraft components, missiles and other products in extreme temperature environments. For example, testing the starting performance of aircraft engines in high altitude low temperatures and high ground temperatures, the sealing of fuel systems in temperature changes, and the stability of avionics equipment ensure that these key components can work properly in the harsh space and atmosphere environment.
Material science research: For the development and performance evaluation of new materials, temperature shock test is an important means. The two-chamber impact test chamber can help researchers understand the physical and chemical properties of materials under different temperature conditions, such as thermal expansion coefficient, strength, toughness, fracture toughness, etc. By conducting temperature shock tests on materials, materials suitable for specific application environments can be screened, supporting the development and innovation of materials science.
Other industries: In addition to the above main application areas, Two Box Impact Chamber also plays an important role in the medical devices, communication equipment, chemical products and other industries. For example, in the medical device industry, it is used to test the reliability of products such as pacemakers and artificial joints; In the communication equipment industry, test the transmission performance and stability of optical fiber cable, switch and other equipment under temperature changes; In the chemical products industry, evaluate the performance changes and aging characteristics of materials such as coatings, plastics and rubber under different temperature conditions.
Product parameter
|
Product name |
Two box type temperature impact test box |
|||||
|
Product model |
BT-2TS100 |
BT-2TS180 |
BT-2TS300 |
BT-2TS1000 |
||
|
Nominal volume |
Unit/L |
100 |
180 |
300 |
1000 |
|
|
Inner size |
Width × depth × height (mm) |
500×500×400 |
600×600×500 |
700×700×600 |
1000×1000×1000 |
|
|
External size |
Width × depth × height (mm) |
1020×1200×1850 |
1200×1500×1900 |
1350×1600×1980 |
2450×1800×1980 |
|
|
Basket size |
Width × depth × height (mm) |
350×350×250 |
450×450×350 |
550×550×450 |
800×800×800 |
|
|
Operating mode |
A.vertical basket B. horizontal basket type |
|||||
|
Performance index |
temperature range |
A,-75℃~200℃ B,-90℃~200℃ C,-120℃~200℃ |
||||
|
Impact range |
A,-55℃~160℃ B,-75℃~160℃ C,-85℃~160℃ |
|||||
|
Temperature fluctuation |
±0.5℃ |
|||||
|
Temperature uniformity |
≤±2.0℃ |
|||||
|
Temperature deviation |
≤±2.0℃ |
|||||
|
heating rate |
RT~+200℃,≤40Min |
|||||
|
Cooling rate |
A,+25℃~-75℃,≤60Min;B,+25℃~-90℃,≤80Min;C,+25℃~-90℃,≤100Min; |
|||||
|
Temperature conversion time |
≤15s |
|||||
|
Temperature recovery time |
≤5Min |
|||||
|
Exposure conditions |
High temperature exposure 30Mins; Low temperature exposure 30Mins |
|||||
|
Refrigeration method |
Compressor refrigeration |
|||||
|
Cooling method |
Air-cooled/water-cooled |
|||||
|
Main components |
Control System |
Siemens programmable controller + touch screen + independent development program |
||||
|
Heating system |
Fully independent system, high efficiency stainless steel finned tube heater |
|||||
|
Cooling System |
Importer-type scroll compressor |
|||||
|
Circulatory system |
Temperature and low noise motor, stainless steel centrifugal impeller |
|||||
|
Main materials |
Carton material |
High-quality carbon steel plate, phosphating electrostatic spray treatment |
||||
|
Inner box material |
International standard SUS304# stainless steel mirror treatment |
|||||
|
Insulation material |
Hard flame retardant polyurethane foam |
|||||
|
Sealing material |
High and low temperature environment-friendly silicone rubber seal |
|||||
|
voltage |
380±10% VAC,50Hz;3L+N+G |
|||||
|
Communication Interface |
RS232 communication interface, USB data interface |
|||||
|
Standard configuration |
1 sample holder, 1 test lead hole, 1 silicone plug |
|||||
|
Optional accessories |
Recorder, Remote Control Software, Insulated Sample Holder, Split Manipulator, Dry Air Purge |
|||||
|
safety devices |
Leakage, short circuit, motor overheating, heater overheating, humidification, water shortage, compressor overpressure, overload, multiple overtemperature protection |
|||||
|
Environmental requirements |
Ambient temperature: 5 ~ 35 °C, relative humidity: ≤ 85% RH, no strong vibration, electromagnetic radiation, dust and corrosive substances around; Water supply temperature: ≤ 30 °C, water pressure: 0.1 ~ 0.3MPa, water quality meets industrial water standards; |
|||||
|
Note: 1. temperature performance parameters are in the ambient temperature of 25 °C, studio no load conditions, in accordance with GB/T5170.2-2008 test; 2.according to the specific requirements of users customized non-standard high and low temperature impact test box; 3.This technical information is subject to change without notice. |
||||||
Hot Tags: two-box impact test chamber, China, suppliers, manufacturers, factory, buy, cheap, Temperature Humidity Vibration Composite Test Chamber, Hot air industrial oven, Salt spray corrosion test chamber, Cold impact chamber, IC Tester, Laboratory Electric Heating Chamber