Products Description
Temperature humidity calibration chamber, also known as "constant temperature and humidity test chamber", is a device used to simulate constant temperature and humidity conditions for testing and testing. It usually consists of a sealed test chamber, heating and cooling system, humidification and dehumidification system, and temperature and humidity control system, and is widely used in electronic parts, auto parts, notebooks and other product industries.

Temperature humidity calibration chamber--reliability test
Humidity calibration chamber is widely used in scientific research, product testing, quality control and other fields. It can simulate various climate conditions, such as high temperature, low temperature, humidity, dryness, etc., to test the performance and stability of materials, products or systems under these conditions. It can better help manufacturers to discover the weaknesses and deficiencies of products under various real environmental conditions in advance, test and provide data and information for improving product design, and ensure that the products can work more stably and reliably in actual use.
Products structure
Temperature Humidity Calibration Chamber is composed of temperature system, humidity system, refrigeration system, heating element, cooling element, controller, observation window, universal wheel and other parts.

Features
1. Temperature Humidity Calibration Chamber adopting internationally renowned brand compressors and refrigeration accessories to ensure the stability of the refrigeration system;
2. Special air circulation design, good temperature and humidity distribution uniformity;
3. Full range of microcomputer controllers, color touch screen, Chinese and English system program setting function, USB can export test data;
4. Can display the cause of the fault, easy to eliminate;
5. Ultra-quiet design, effectively reducing the equipment operation noise;
6 Multiple safety protections: refrigerant high pressure protection, compressor overload protection, current overload protection, over-temperature protection, leakage protection. It can ensure the safety of samples and more effectively protect the equipment components from overload operation, greatly reduce the occurrence rate of equipment failure, and make the equipment operation more stable and reliable.

Technical solution
|
Model |
B-TH-80 (A~G) |
B-TH-150 (A~G) |
B-TH-225 (A~G) |
B-TH-408 (A~G) |
B-TH-608 (A~G) |
B-TH-800 (A~G) |
B-TH-1000 (A~G) |
||
|
Inside size WxHxD (cm) |
40x50x40 |
50x60x50 |
50x75x60 |
80x85x60 |
80x95x80 |
100x100x80 |
100x100x100 |
||
|
Outside size WxHxD (cm) |
95x145x105 |
105x175x97 |
115x190x97 |
135x185x120 |
145x185x137 |
145x210x130 |
147x210x140 |
||
|
Temperature range |
0℃~+150℃ |
||||||||
|
Humidity range |
20%~98%R.H.(10%-98%R.H/5%~98%R.H is the specific condition) |
||||||||
|
Temperature Humidity Calibration Chamber Performance |
|||||||||
|
1. Temperature range |
0℃~ +150℃ |
||||||||
|
2. Humidity range |
20%R.H ~ 98%R.H |
||||||||
|
3.Temperature and humidity chart |
|
||||||||
|
4. Temperature deviation |
≤ ±2.0 ℃ (no load, constant state) |
||||||||
|
5.Temperature resolution |
0.1℃ |
||||||||
|
6.Temperature uniformity |
≤ ±2℃ (no load, constant state) |
||||||||
|
7. Humidity fluctuation |
±1.0%R.H |
||||||||
|
8. Humidity deviation |
≤ ±2%R.H |
||||||||
|
9. Humidity uniformity |
>75%RH: ≤±2-3%RH; <75%RH: ≤±3-5%RH (humid heat type only) |
||||||||
|
10. Humidity resolution |
1.0%R.H |
||||||||
|
11. Heating time |
3~5℃/min (non-linear no-load) |
||||||||
|
12. Cooling time |
0.7~1.2℃/min (non-linear no-load) |
||||||||
Standard
GB/T2423.1-2008 Test A: Low temperature test method
GB/T2423.2-2008 Test B: High temperature test method
GJB150.3A-2009 high temperature test
GJB150.4A-2009 Low temperature test
GB3423.22-2008 Test method for speed of temperature change
GBT2424.5-2006 Temperature test chamber performance confirmation
GB/T 10589-2008 low temperature test technical conditions
GB/T2423.3-2008 Test method for constant greenhouse
GJB150.9A-2009 Greenhouse test method
G/BT2423.4-2008 Alternating humid heat method
GB/T10586-2006 Wet heat test chamber technical conditions
GB/T2424.6-2006 Temperature/humidity test chamber performance confirmation
GB/T2424.7-2006 Measurement of temperature test chamber
Components of Temperature Humidity Calibration Chamber
Inner and outer chamber:The inner and outer chamber are made of high-quality brushed stainless steel, which is sturdy and durable. The exterior is painted and sprayed with plastic, making the equipment more beautiful.
Control System:Controller touch screen, including lighting switch, USB interface (on the control panel); main power switch, over-temperature protection setting device, and communication interface.
Cooling system:The compressor can be selected as single-stage (air-cooled) or double-stage refrigeration system (water-cooled). The evaporator adopts a finned heat exchanger and the refrigerant adopts environmentally friendly R404a/R23 with an ozone depletion index of 0.
Heating system:The heater adopts nickel-chromium alloy electric heating wire heater;
Heater control method: SSR (solid-state relay) contactless equicyclic pulse width modulation.
Humidification system:The humidification method adopts electric steam humidification, and the equipment has automatic water replenishment function.
Noise reduction system:The low-temperature pipeline is equipped with shock-absorbing process pipes to reduce the noise caused by the operation of the compressor; the refrigeration unit uses shock-absorbing springs or rubber pads for shock absorption and noise reduction; the inner side of the unit enclosure is affixed with sound-absorbing materials for noise reduction.
Hot Tags: temperature humidity calibration chamber, China, suppliers, manufacturers, factory, buy, cheap, Three Box Type Temperature Schock Chamber, Fast heat and cooling cycling chamber, Semiconductor Materials Test chamber, Printed circuit board tester, Muffle Furnace Oven, Heating up testchamber